PRINCIPLE

Oasis Iceberg

2021-09-26

Compound flow double inlet air closed cooling tower

Vantage

Adopting compound flow cooling method and matching dehydrator, the drift rate is low;

Cooling medium closed loop, no impurities into the medium to ensure the purity of the medium.

The use of pure water in the internal circulation medium, no scaling, no blockage of the pipeline.

Spray water to the condenser outer wall completely wet, to avoid the formation of scale in the dry point parts, will greatly improve the efficiency of the system.

Small footprint, can be shifted and placed as needed, low maintenance cost.

Compound flow closed cooling tower for anti-freezing energy-saving cooling tower, in the northern region of lower temperatures when the equipment does not run, the condenser water automatically back to the water tank, thus ensuring that the equipment is not frozen.

Automatic digital temperature control, energy saving and environmental protection.

 

Cycle of three

1, internal circulation: the circulating medium through the heat source heat transfer after warming up into the heat transfer coil, through the heat transfer coil will heat through the pipe wall, conduction to the external water film, the water film absorbs heat into the latent heat of vaporization, the phase into steam, the circulating medium is cooled, and then sent to the production of heat sources.

 

 

2, external circulation: spray water from the sink to the spray system, uniformly sprayed to the outside of the pipe to form a water film, part of the water vapor, discharged through the fan, the spray water is not evaporated fall to the sink after the cycle again.

 

 

3, air circulation: dry cold air from the upper part of the composite flow closed tower into the downward high-speed skimming coil, take away the evaporated water vapor, take away the heat energy, humidity increases, discharged by the extractor fan out of the tower. The air entering from the side passes through the packing, fully exchanges heat with the spray water, and reduces the temperature of the spray water.

 

Working Process

1, air-cooled + spray shower spray water through the spray pump into a mist sprayed to the surface of the heat pipe, resulting in a very thin film of water wrapped around the heat pipe.

2, by the heat exchanger tube inside the high temperature medium heating, prompting the water film evaporation, water evaporation from the liquid state into a gaseous state, absorbing the latent heat of vaporization, the same state than the temperature rise in the medium, more than dozens of times the absorption of heat energy.

3, at the same time, due to the fan's strong pumping force, quickly evaporated water vapor away, low humidity air from the inlet style grille was filled in, so the cycle continues; water vapor away from part of the water droplets, by the water collector recovery drops, and not evaporated spray water, are back to the bottom of the water collection tank, pumped out of the spray pump, pumped into the upper part of the spray pipeline, re-use.

      (For details, please refer to the above video "Compound flow double inlet air closed cooling tower working principle animation")

 

 

Oasis Ice Peak Brand Advantage

Focus on 21 years, because of focus, so professional, experienced, quality.

19 patents, patent-supported, reliable technology, excellent performance, stable operation

Covering an area of 40 acres, strong strength, strong backing, long-term cooperation, after-sales worry-free!