PRINCIPLE

Oasis Iceberg

2021-09-26

Compound flow closed cooling tower

Vantage

Adopting compound flow cooling method and matching dehydrator, the drift rate is low;

Cooling medium closed circulation, no impurities into the medium to ensure the purity of the medium.

Water circulation of water using soft water, no scaling, not blocking the pipeline.

The spray water drenches the outer wall of the condenser completely, which avoids the formation of scale in the dry point part and improves the efficiency of the system to an effective degree.

Small footprint, can be moved and placed as needed, low maintenance cost.

Compound flow closed cooling tower for anti-freezing energy-saving cooling tower, in the northern region of lower temperatures when the equipment does not run, the condenser water automatically back to the water tank, thus ensuring that the equipment is not frozen.

Automatic digital temperature control, energy saving and environmental protection.

 

 

Cycle of three

1, internal circulation: the circulating medium through the heat source heat transfer after warming into the heat transfer coil, through the heat transfer coil will be heat through the pipe wall, conduction to the external water film, the water film absorbs heat into the latent heat of vaporization, the phase into steam, the circulating medium is cooled, and then sent to the production of heat sources.

2, external circulation: spray water from the sink to the spray system, uniformly sprayed to the outside of the pipe to form a water film, part of the water vapor, through the fan discharged, not evaporated spray water falls to the sink after the cycle again.

3, air circulation: dry and cold air from the upper part of the composite flow closed tower into the downward high-speed skimming coil, take away the evaporated water vapor, take away the heat energy, humidity increases, discharged by the extractor fan outside the tower. The air entering from the side passes through the packing, fully exchanges heat with the spray water, and reduces the temperature of the spray water.

 

Suitability

1, lower outlet temperature: because of this structure spray water temperature is low, spray water cooling after the circulating medium temperature is lower;

2, adjacent to the arrangement: because of this structure into the air, in the upper part and a side, the rest of the side without air inlet, can be adjacent to the arrangement, more than one can be made into a module to deal with large flow projects.

 

Working process

1, air-cooled + spray shower spray water through the spray pump into a mist sprayed to the surface of the heat pipe, resulting in a very thin film of water wrapped around the heat pipe.

2, by the heat exchanger tube inside the high temperature medium heating, prompting the water film evaporation, water evaporation from the liquid state into a gaseous state, absorbing the latent heat of vaporization, the same state than the temperature rise in the medium, more than dozens of times the absorption of heat energy.

3, at the same time, due to the fan's strong pumping force, quickly evaporated water vapor away, low humidity air from the inlet style grille was filled in, so the cycle continues; water vapor away from part of the water droplets, water collector by the recovery of drops, and the evaporation of spray water, are back to the bottom of the water collection tank, pumped out by the spray pump, pumped into the upper part of the spray pipeline, re-use.

 

 

Oasis Ice Peak Brand Advantage

Focus on 21 years, because of focus, so professional, experienced, quality.

19 patents, patent-supported, reliable technology, excellent performance, stable operation

Covering an area of 40 acres, strong strength, strong backing, long-term cooperation, after-sales worry-free!